FIBERTEK IV-MM LED & SM LASER KIT

R164010

Attenuation/insertion loss (dB) measurement
Multimode and single-mode options
Encircled Flux compliant (optional)
Built-in visible light source for troubleshooting
Full Tier 1 fibre certification
Complies with TIA/ISO/IEC

$13,995 MSRP

Product highlights

FiberTEK IV combination MM/SM kit with LED MM sources and laser SM sources. Compatible with all LanTEK IV models.

Kit Content

Two multimode FiberTEK IV modules, two single-mode FiberTEK IV modules, lockable semi-rigid carrying case, SC, FC, ST adaptors for modules (2 ea.), SC-SC patch cords, 6 x 9μm, 6 x 50μm compliant to ISO/IEC 14763-3 standard, quick reference guide. Compatible with LanTEK IV.

Key features

FIBRE CABLE CERTIFIERS – FIBERTEK III

Attenuation/insertion loss (dB) measurement
Multimode and single-mode options
Encircled Flux compliant (optional)
Built-in visible light source for troubleshooting
Full Tier 1 fibre certification
Complies with TIA/ISO/IEC
RRP ex VAT £3,245 to £6,550

OverviewFeaturesApplicationsModelsAccessories Downloads FAQ

Setup Wizard
Select field calibration (1-Jumper|3-Jumper) and measurement modes (Loopback|Normal), (Uni-Directional|Bi-Directional)

Auto-test
Perform auto-tests using the intuitive graphical interface to reduce mistakes and ensure accurate certification results.

Review Results
Tier 1 certification results display:

ISO/TIA/IEEE test standard
Pass/Fail result
dB loss of each fibre at each wavelength
dB loss in each direction (when testing bi-directionally)
Fibre link length
dB margin / headroom

The main applications for FiberTEK III is the testing of fibre optic MM and SM cabling in LAN and campus applications. Its key feature is to measure attenuation and length of a fibre optic link. (also known as “Tier 1 Certification”). The test can be carried out during installation as well as during fault finding:

Certifying cable performance to ISO 11801 and TIA 568-C standards
Meet cabling specifications as required by engineers, designers and clients
Provide proof of good workmanship when the client does not require certification tests
Avoid call-backs by identifying faults while onsite
Convert warranty call-backs into chargeable service calls
Dispute resolution between network equipment/configuration versus cable installation
Installation of:

building backbone cabling (“secondary cabling”)
inter building cabling and campus cabling (primary cabling)
FTTD (Fibre To The Desk) cabling (“tertiary cabling”)
Cabling for building automation
Cabling for industrial automation
SAT cabling

FIBRE CABLE CERTIFIERS – FIBERTEK III

Attenuation/insertion loss (dB) measurement
Multimode and single-mode options
Encircled Flux compliant (optional)
Built-in visible light source for troubleshooting
Full Tier 1 fibre certification
Complies with TIA/ISO/IEC
RRP ex VAT £3,245 to £6,550

OverviewFeaturesApplicationsModelsAccessories Downloads FAQ

Setup Wizard
Select field calibration (1-Jumper|3-Jumper) and measurement modes (Loopback|Normal), (Uni-Directional|Bi-Directional)

Auto-test
Perform auto-tests using the intuitive graphical interface to reduce mistakes and ensure accurate certification results.

Review Results
Tier 1 certification results display:

ISO/TIA/IEEE test standard
Pass/Fail result
dB loss of each fibre at each wavelength
dB loss in each direction (when testing bi-directionally)
Fibre link length
dB margin / headroom

The main applications for FiberTEK III is the testing of fibre optic MM and SM cabling in LAN and campus applications. Its key feature is to measure attenuation and length of a fibre optic link. (also known as “Tier 1 Certification”). The test can be carried out during installation as well as during fault finding:

Certifying cable performance to ISO 11801 and TIA 568-C standards
Meet cabling specifications as required by engineers, designers and clients
Provide proof of good workmanship when the client does not require certification tests
Avoid call-backs by identifying faults while onsite
Convert warranty call-backs into chargeable service calls
Dispute resolution between network equipment/configuration versus cable installation
Installation of:

building backbone cabling (“secondary cabling”)
inter building cabling and campus cabling (primary cabling)
FTTD (Fibre To The Desk) cabling (“tertiary cabling”)
Cabling for building automation
Cabling for industrial automation
SAT cabling

Customer reviews

0.0 out of 5 stars (based on 0 reviews)
Excellent0%
Very good0%
Average0%
Poor0%
Terrible0%

There are no reviews yet. Be the first one to write one.